Salta ai contenuti
ricarica intelligente

EVBox Elvi

Questa pagina mostra la versione nightly. Passa alla versione release.

If the device is installed with phaserotation, this can be configured in the EVBox Elvi with the EVBox Connect App so the voltages and currents are reported on the correct phase. This is necessary for the loadmanagement of EVBox, but for the usage with evcc the phaserotation should not be configured inside the EVBox Elvi. Especially if the Elvi was used in a EVBox loadmanagement, it should be ensured in the Installationmode of the EVBox Connect App that the string under "Phaserotation" ends with "RST".

Funzionalità supportate

  • Riducibile: La potenza assorbita può essere ridotta (ad es. § 14a EnWG). Vedi Limite esterno.

Parametri

NomeDescrizioneValoreLivello
stationidStation ID

Unique identifier of the charger. Automatically detected once the charger connects.

Esempio: EVB-P12354
facoltativo
meterMeter ID
Predefinito: true
facoltativo
connectorConnector number

For multi-connector stations. Numbering starts at 1.

Predefinito: 1
avanzato
chargingprofileCharging profile type

Use TxProfile only if the charger ignores TxDefaultProfile changes during an active transaction. Without a transaction, TxDefaultProfile is still used; an active transaction must report its ID. TxProfile expires with its transaction. The default profile is restored on the next control cycle. If evcc is offline then, the charger may charge without this limit until it reconnects.

Predefinito: TxDefaultProfile
avanzato
remotestartStart remote transaction on vehicle connection

Only enable this option if there is no way to initiate transactions from the charger side! This is only the case if e.g. no RFID reader is available and charging processes would have to be released individually via app. Normally, the charger should always be configured at the device so that either an RFID card is used for activation or the charger is set to "Autostart", "Free Charging" or similar. First check the documentation and configuration possibilities of the charger, ask the manufacturer if necessary! (Uses OCPP RemoteStartTransaction)

avanzato
idtagAuthentication token

This option is only required in exceptional cases if the charger requires a specific token for accepting external transactions. (Uses OCPP RemoteStartTransaction)

Esempio: evcc
avanzato
connecttimeoutTimeout for registration

Timeout for the registration of the charging point

Predefinito: 5m
avanzato
metervaluesMeter values for transmission

Manual specification of the meter values to be configured (MeterValuesSampledData)

Esempio: Energy.Active.Import.Register,Power.Active.Import,SoC,Current.Offered,Power.Offered,Current.Import,Voltage
avanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

chargers:
- name: my_charger
type: template
template: ocpp-evbox-elvi
stationid: EVB-P12354 # Station ID, Unique identifier of the charger. Automatically detected once the charger connects. (optional)
meter: true # Meter ID, optional
connector: 1 # Connector number, For multi-connector stations. Numbering starts at 1. (optional)
chargingprofile: TxDefaultProfile # Charging profile type, Use TxProfile only if the charger ignores TxDefaultProfile changes during an active transaction. Without a transaction, TxDefaultProfile is still used; an active transaction must report its ID. TxProfile expires with its transaction. The default profile is restored on the next control cycle. If evcc is offline then, the charger may charge without this limit until it reconnects. [TxDefaultProfile, TxProfile] (optional)
remotestart: # Start remote transaction on vehicle connection, Only enable this option if there is no way to initiate transactions from the charger side! This is only the case if e.g. no RFID reader is available and charging processes would have to be released individually via app. Normally, the charger should always be configured at the device so that either an RFID card is used for activation or the charger is set to "Autostart", "Free Charging" or similar. First check the documentation and configuration possibilities of the charger, ask the manufacturer if necessary! (Uses OCPP RemoteStartTransaction) (optional)
idtag: evcc # Authentication token, This option is only required in exceptional cases if the charger requires a specific token for accepting external transactions. (Uses OCPP RemoteStartTransaction) (optional)
connecttimeout: 5m # Timeout for registration, Timeout for the registration of the charging point (optional)
metervalues: Energy.Active.Import.Register,Power.Active.Import,SoC,Current.Offered,Power.Offered,Current.Import,Voltage # Meter values for transmission, Manual specification of the meter values to be configured (MeterValuesSampledData) (optional)