Connect the relay contacts of the control box to the digital inputs of the module. The module must provide the inputs as discrete inputs (function code 02), a closed contact reads as active.

Parametri

NomeDescrizioneValoreLivello
idID Modbus
Predefinito: 1
intobbligatorio
hostIndirizzo IP o hostname
Esempio: 192.0.2.2
obbligatorio
portPorta
Predefinito: 502
intobbligatorio
maxconsumptionpower [W]Guaranteed minimum power (Pmin)

Power limit applied to the root circuit while the limit is active.

facoltativo
w4inputW4 input

Digital input number for the W4 signal (Dimmer for controllable loads), counting from 1 (first input = 1)

Predefinito: 1
facoltativo
w3inputW3 input

Digital input number for the W3 signal (Zero export, 0%), counting from 1 (first input = 1)

Predefinito: 2
facoltativo
productionnominalmax [Wp]Installed generator power

Rated generator/module power of the installation (reference value according to § 9 EEG).

facoltativo
s1inputS1 input

Digital input number for the S1 signal (60% export power limit), counting from 1 (first input = 1)

Esempio: 3
facoltativo
s2inputS2 input

Digital input number for the S2 signal (30% export power limit), counting from 1 (first input = 1)

Esempio: 4
facoltativo
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

hems:
type: template
template: fnn-modbus
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
maxconsumptionpower: # Guaranteed minimum power (Pmin) (W), Power limit applied to the root circuit while the limit is active.
w4input: 1 # W4 input, Digital input number for the W4 signal (Dimmer for controllable loads), counting from 1 (first input = 1)
w3input: 2 # W3 input, Digital input number for the W3 signal (Zero export, 0%), counting from 1 (first input = 1)
productionnominalmax: # Installed generator power (Wp), Rated generator/module power of the installation (reference value according to § 9 EEG). (optional)
s1input: 3 # S1 input, Digital input number for the S1 signal (60% export power limit), counting from 1 (first input = 1) (optional)
s2input: 4 # S2 input, Digital input number for the S2 signal (30% export power limit), counting from 1 (first input = 1) (optional)