Salta ai contenuti
ricarica intelligente

Vaillant SensoNET (API)

Questa pagina mostra la versione nightly. Passa alla versione release.

The boost function heats hot water or a boost zone. The boost zone is identified by the ID. The boost temperature is specified in degrees Celsius. If boost temperature is specified, the boost zone is activated, otherwise hot water. Note, if the appliance's DHW operation mode is set to "off" so that evcc fully controls hot water, the appliance no longer runs its weekly legionella protection. Make sure to periodically heat the water to disinfection temperature yourself (e.g. via time program or a forced boost).

Parametri

NomeDescrizioneValoreLivello
userUsername

e.g. email address, user id, etc.

facoltativo
passwordPassword

Service account password

facoltativo
realmRegion
Predefinito: germany
facoltativo
zoneBoost zone IDfacoltativo
setpointBoost temperaturefacoltativo
systemName of the system

Required if multiple systems are present in the account

facoltativo
reboostReboost interval

Wait time after which Boost is started again.

Predefinito: 15m
avanzato
hysteresis [°C]Reboost Hysteresisavanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

chargers:
- name: my_heating
type: template
template: vaillant
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
realm: germany # Region, [albania, austria, belgium, bosnia, bulgaria, croatia, cyprus, czechrepublic, denmark, estonia, finland, france, georgia, germany, greece, hungary, ireland, italy, kosovo, latvia, lithuania, luxembourg, moldavia, netherlands, new-zealand, north-macedonia, norway, poland, portugal, romania, serbia, slovakia, slovenia, spain, sweden, switzerland, turkiye, ukraine, unitedkingdom, uzbekistan] (optional)
zone: # Boost zone ID, optional
setpoint: # Boost temperature, optional
system: # Name of the system, Required if multiple systems are present in the account (optional)
reboost: 15m # Reboost interval, Wait time after which Boost is started again. (optional)
hysteresis: # Reboost Hysteresis (°C), optional