Ferroamp EnergyHub
Modbus TCP has to be enabled for the EnergyHub by the installer or Ferroamp support. The interface is only reachable via the EnergyHub's Ethernet interface. Grid values are measured by the external current transformers (CTs) at the grid connection point.
Funzionalità supportate
- Controllo batteria: Controllo esterno della carica e della scarica della batteria domestica tramite evcc.
Ambiti di utilizzo
- Contatore di rete
- Produzione solare
- Batteria
Parametri
| Nome | Descrizione | Valore | Livello |
|---|---|---|---|
id | ID Modbus | int | obbligatorio |
host | Indirizzo IP o hostname | obbligatorio | |
port | Porta | int | obbligatorio |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | facoltativo | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | facoltativo | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | facoltativo | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | facoltativo |
Esempio di configurazione per evcc.yaml
Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.
meters: - name: my_grid type: template template: ferroamp-energyhub usage: grid
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Portmeters: - name: my_pv type: template template: ferroamp-energyhub usage: pv
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Portmeters: - name: my_battery type: template template: ferroamp-energyhub usage: battery
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)