Ambiti di utilizzo

  • Contatore di rete
  • Produzione solare
  • Contatore del caricabatterie

Parametri

NomeDescrizioneValoreLivello
hostIP address or hostname
Esempio: 192.0.2.2
facoltativo
deviceDevice address/Serial number

Homematic device id like shown in the CCU web user interface.

Esempio: 0001EE89AAD848
facoltativo
meterchannelMeter channel number

Homematic meter channel number like shown after the device id separated with a colon in the CCU web user interface.

Predefinito: 6
Esempio: HMIP-PSM=6, HMIP-FSM+HMIP-FSM16=5, HM-ES-TX-WM=1
facoltativo
userUsername

e.g. email address, user id, etc.

facoltativo
passwordPassword

Service account password

facoltativo
cacheXML-RPC API cache duration

In case of duty cycle problems try a cache setting of 30s.

Predefinito: 1s
Esempio: 5m
avanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

meters:
- name: my_grid
type: template
template: homematic
usage: grid
host: 192.0.2.2 # IP address or hostname
device: 0001EE89AAD848 # Device address/Serial number, Homematic device id like shown in the CCU web user interface.
meterchannel: 6 # Meter channel number, Homematic meter channel number like shown after the device id separated with a colon in the CCU web user interface.
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
cache: 1s # XML-RPC API cache duration, In case of duty cycle problems try a cache setting of 30s. (optional)
meters:
- name: my_pv
type: template
template: homematic
usage: pv
host: 192.0.2.2 # IP address or hostname
device: 0001EE89AAD848 # Device address/Serial number, Homematic device id like shown in the CCU web user interface.
meterchannel: 6 # Meter channel number, Homematic meter channel number like shown after the device id separated with a colon in the CCU web user interface.
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
cache: 1s # XML-RPC API cache duration, In case of duty cycle problems try a cache setting of 30s. (optional)
meters:
- name: my_charger
type: template
template: homematic
usage: charge
host: 192.0.2.2 # IP address or hostname
device: 0001EE89AAD848 # Device address/Serial number, Homematic device id like shown in the CCU web user interface.
meterchannel: 6 # Meter channel number, Homematic meter channel number like shown after the device id separated with a colon in the CCU web user interface.
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
cache: 1s # XML-RPC API cache duration, In case of duty cycle problems try a cache setting of 30s. (optional)