Salta ai contenuti
ricarica intelligente

ioBroker

Questa pagina mostra la versione nightly. Passa alla versione release.

The rest-api adapter (not simple-api) must be installed on the ioBroker instance being used. It can be configured stand-alone or as an extension of a web adapter. The parameter webextension determines whether the adapter is configured as a web extension. Default is true, which means that the adapter is configured as a web extension. Authentication can only be performed using basic authentication. If no password is provided, no authentication will be performed. When specifying the entities for the individual measured values, ensure that they are correctly URL-encoded. For example, shelly.0.SHEM-3#8CAAB561991E#1.Total.ConsumedPower becomes shelly.0.SHEM-3%238CAAB561991E%231.Total.ConsumedPower

Ambiti di utilizzo

  • Contatore di rete
  • Produzione solare
  • Batteria
  • Contatore del caricabatterie

Parametri

NomeDescrizioneValoreLivello
uriThe full uri of the host to query

HTTP(S) address

Esempio: https://iobroker.homelab.lan:8082
facoltativo
webextensionRest as web extension

Determines whether the REST adapter is installed stand alone or as a web extension. Should 404 errors occur, try changing the value.

Predefinito: true
facoltativo
userUsername

e.g. email address, user id, etc.

facoltativo
passwordPassword

Service account password

facoltativo
power [W]Powerfacoltativo
soc [%]State of Chargefacoltativo
capacity [kWh]Battery capacity
Esempio: 50
facoltativo
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Predefinito: 0
Esempio: 25
facoltativo
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Predefinito: 100
Esempio: 95
facoltativo
cacheCache

Time interval for data refresh

Esempio: 5m
avanzato
energy [kWh]Meter readingavanzato
currentL1 [A]L1 currentavanzato
currentL2 [A]L2 currentavanzato
currentL3 [A]L3 currentavanzato
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

avanzato
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avanzato
maxacpower [W]Maximum AC power of the hybrid inverter
Predefinito: 0
Esempio: 5000
avanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

meters:
- name: my_grid
type: template
template: iobroker
usage: grid
uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address
webextension: true # Rest as web extension, Determines whether the REST adapter is installed stand alone or as a web extension. Should 404 errors occur, try changing the value. (optional)
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
power: # Power (W), optional
soc: # State of Charge (%), optional
cache: 5m # Cache, Time interval for data refresh (optional)
energy: # Meter reading (kWh), optional
currentL1: # L1 current (A), optional
currentL2: # L2 current (A), optional
currentL3: # L3 current (A), optional
meters:
- name: my_pv
type: template
template: iobroker
usage: pv
uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address
webextension: true # Rest as web extension, Determines whether the REST adapter is installed stand alone or as a web extension. Should 404 errors occur, try changing the value. (optional)
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
power: # Power (W), optional
soc: # State of Charge (%), optional
cache: 5m # Cache, Time interval for data refresh (optional)
energy: # Meter reading (kWh), optional
currentL1: # L1 current (A), optional
currentL2: # L2 current (A), optional
currentL3: # L3 current (A), optional
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
meters:
- name: my_battery
type: template
template: iobroker
usage: battery
uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address
webextension: true # Rest as web extension, Determines whether the REST adapter is installed stand alone or as a web extension. Should 404 errors occur, try changing the value. (optional)
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
power: # Power (W), optional
soc: # State of Charge (%), optional
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
cache: 5m # Cache, Time interval for data refresh (optional)
energy: # Meter reading (kWh), optional
currentL1: # L1 current (A), optional
currentL2: # L2 current (A), optional
currentL3: # L3 current (A), optional
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)
meters:
- name: my_charger
type: template
template: iobroker
usage: charge
uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address
webextension: true # Rest as web extension, Determines whether the REST adapter is installed stand alone or as a web extension. Should 404 errors occur, try changing the value. (optional)
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
power: # Power (W), optional
soc: # State of Charge (%), optional
cache: 5m # Cache, Time interval for data refresh (optional)
energy: # Meter reading (kWh), optional
currentL1: # L1 current (A), optional
currentL2: # L2 current (A), optional
currentL3: # L3 current (A), optional