Questa pagina mostra la versione nightly. Passa alla versione release.

The battery's local mode must be enabled in the manufacturer's app. Furthermore, the device's IP address must be set to a fixed, permanent IP address in the router. An external meter (e.g., Shelly) measuring the grid connection point must be connected to the battery via the manufacturer's app. It is required for the grid usage, and also for the battery usage, because the normal battery mode enables the device's zero feed-in regulation, which reads this meter.

Funzionalità supportate

  • Controllo batteria: Controllo esterno della carica e della scarica della batteria domestica tramite evcc.

Ambiti di utilizzo

  • Contatore di rete
  • Produzione solare
  • Batteria

Parametri

NomeDescrizioneValoreLivello
modelModel

standard for the SunEnergyXT 500, pro for the SunEnergyXT 500 PRO. Determines the maximum AC and discharge power (800 W resp. 2400 W).

facoltativo
hostIP address or hostname
Esempio: 192.0.2.2
facoltativo
capacity [kWh]Battery capacity

Total storage capacity: head unit 5 kWh, each extension pack adds 5 kWh. So 5 (head unit only), 10 (+1 extension) or 15 (+2 extensions). The number of detected battery packs is reported in the ON field of /read.

Predefinito: 5
Esempio: 50
facoltativo
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Predefinito: 0
Esempio: 25
facoltativo
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Predefinito: 100
Esempio: 95
facoltativo
maxacpower [W]Maximum AC power of the hybrid inverter
Predefinito: 0
Esempio: 5000
avanzato
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

Predefinito: 2400
avanzato
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avanzato
cacheCache

Time interval for data refresh

Predefinito: 2s
Esempio: 5m
avanzato
timeoutTimeout
Predefinito: 10s
Esempio: 10s
avanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

meters:
- name: my_grid
type: template
template: sunenergyxt-500
usage: grid
model: # Model, `standard` for the SunEnergyXT 500, `pro` for the SunEnergyXT 500 PRO. Determines the maximum AC and discharge power (800 W resp. 2400 W). [standard, pro]
host: 192.0.2.2 # IP address or hostname
cache: 2s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional
meters:
- name: my_pv
type: template
template: sunenergyxt-500
usage: pv
model: # Model, `standard` for the SunEnergyXT 500, `pro` for the SunEnergyXT 500 PRO. Determines the maximum AC and discharge power (800 W resp. 2400 W). [standard, pro]
host: 192.0.2.2 # IP address or hostname
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
cache: 2s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional
meters:
- name: my_battery
type: template
template: sunenergyxt-500
usage: battery
model: # Model, `standard` for the SunEnergyXT 500, `pro` for the SunEnergyXT 500 PRO. Determines the maximum AC and discharge power (800 W resp. 2400 W). [standard, pro]
host: 192.0.2.2 # IP address or hostname
capacity: 5 # Battery capacity (kWh), Total storage capacity: head unit 5 kWh, each extension pack adds 5 kWh. So 5 (head unit only), 10 (+1 extension) or 15 (+2 extensions). The number of detected battery packs is reported in the `ON` field of `/read`. (optional)
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
maxchargepower: 2400 # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)
cache: 2s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional