Salta ai contenuti
ricarica intelligente

Tesla Powerwall (pypowerwall-server)

Questa pagina mostra la versione nightly. Non esiste ancora una versione release.

Uses pypowerwall-server as backend. Reads come from its proxy API, battery control uses its authenticated /control/* routes. For battery control, PW_CONTROL_SECRET must be set on the server; reserve_hold requires pypowerwall-server v0.10.0 or later. Since pypowerwall-server v0.14.0 the server can optionally serve HTTPS on port 8775. Without a TLS reverse proxy or the HTTPS listener it stays plain HTTP; with controlSecret, prefer HTTPS or a trusted network.

Funzionalità supportate

  • Controllo batteria: Controllo esterno della carica e della scarica della batteria domestica tramite evcc.

Ambiti di utilizzo

  • Contatore di rete
  • Produzione solare
  • Batteria

Parametri

NomeDescrizioneValoreLivello
hostIP address or hostname
Esempio: 192.0.2.2
facoltativo
portPort
Predefinito: 8675
facoltativo
capacity [kWh]Battery capacity
Esempio: 50
facoltativo
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Predefinito: 0
Esempio: 25
facoltativo
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Predefinito: 100
Esempio: 95
facoltativo
schemaSchema

Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener.

Predefinito: http
avanzato
insecureAccept self-signed certificatesavanzato
cacheCache

Time interval for data refresh

Predefinito: 1s
Esempio: 5m
avanzato
controlSecretControl secret

Value of PW_CONTROL_SECRET. Required for battery control, omit for read-only use.

avanzato
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

avanzato
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

meters:
- name: my_grid
type: template
template: tesla-powerwall-pypowerwall-server
usage: grid
host: 192.0.2.2 # IP address or hostname
port: 8675 # Port, optional
schema: http # Schema, Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener. [https, http] (optional)
insecure: # Accept self-signed certificates, optional
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: tesla-powerwall-pypowerwall-server
usage: pv
host: 192.0.2.2 # IP address or hostname
port: 8675 # Port, optional
schema: http # Schema, Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener. [https, http] (optional)
insecure: # Accept self-signed certificates, optional
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: tesla-powerwall-pypowerwall-server
usage: battery
host: 192.0.2.2 # IP address or hostname
port: 8675 # Port, optional
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
schema: http # Schema, Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener. [https, http] (optional)
insecure: # Accept self-signed certificates, optional
cache: 1s # Cache, Time interval for data refresh (optional)
controlSecret: # Control secret, Value of PW_CONTROL_SECRET. Required for battery control, omit for read-only use. (optional)
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)