Victron Energy
For grid usage, a grid meter VRM instance is require to enabled load management.
Funzionalità supportate
- Controllo batteria: Controllo esterno della carica e della scarica della batteria domestica tramite evcc.
Ambiti di utilizzo
- Contatore di rete
- Produzione solare
- Batteria
Parametri
| Nome | Descrizione | Valore | Livello |
|---|---|---|---|
id | ID Modbus | int | obbligatorio |
host | Indirizzo IP o hostname | obbligatorio | |
port | Porta | int | obbligatorio |
meterid | Grid meter VRM instance Can be read out in VRM portal or via remoteUI. | facoltativo | |
capacity [kWh] | Battery capacity | facoltativo | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | facoltativo | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | facoltativo | |
maxacpower [W] | Maximum AC power of the hybrid inverter | avanzato | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | avanzato | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | avanzato |
Esempio di configurazione per evcc.yaml
Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.
meters: - name: my_grid type: template template: victron-energy usage: grid
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port meterid: # Grid meter VRM instance, Can be read out in VRM portal or via remoteUI. (optional)meters: - name: my_pv type: template template: victron-energy usage: pv
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optionalmeters: - name: my_battery type: template template: victron-energy usage: battery
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)