Salta ai contenuti
ricarica intelligente

vzlogger

Questa pagina mostra la versione nightly. Passa alla versione release.

Ambiti di utilizzo

  • Contatore di rete

Parametri

NomeDescrizioneValoreLivello
hostIP address or hostname
Esempio: 192.0.2.2
facoltativo
uuidThe vzlogger channel uuid for powerfacoltativo
portPort
Predefinito: 8081
facoltativo
scaleScale factor power

Multiply power raw value by this factor

Predefinito: 1
avanzato
energyuuidMeter reading

The vzlogger channel uuid for the meter reading (OBIS Code 1.8.0, electricity consumption)

avanzato
returnenergyuuidReturn meter reading

The vzlogger channel uuid for the return meter reading (OBIS Code 2.8.0)

avanzato
energyscaleScale factor energy

Multiply energy raw value by this factor

Predefinito: 0.001
avanzato
l1currentuuidCurrent on phase 1

The vzlogger channel uuid for current on phase 1 (OBIS Code 31.7.0)

avanzato
l2currentuuidCurrent on phase 2

The vzlogger channel uuid for current on phase 2 (OBIS Code 51.7.0)

avanzato
l3currentuuidCurrent on phase 3

The vzlogger channel uuid for current on phase 3 (OBIS Code 71.7.0)

avanzato
l1poweruuidPower on phase 1

The vzlogger channel uuid for power on phase 1 (OBIS Code 36.7.0)

avanzato
l2poweruuidPower on phase 2

The vzlogger channel uuid for power on phase 2 (OBIS Code 56.7.0)

avanzato
l3poweruuidPower on phase 3

The vzlogger channel uuid for power on phase 3 (OBIS Code 76.7.0)

avanzato
l1voltageuuidVoltage on phase 1

The vzlogger channel uuid for voltage on phase 1 (OBIS Code 32.7.0)

avanzato
l2voltageuuidVoltage on phase 2

The vzlogger channel uuid for voltage on phase 2 (OBIS Code 52.7.0)

avanzato
l3voltageuuidVoltage on phase 3

The vzlogger channel uuid for voltage on phase 3 (OBIS Code 72.7.0)

avanzato
cacheCache

Time interval for data refresh

Predefinito: 1s
Esempio: 5m
avanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

meters:
- name: my_grid
type: template
template: vzlogger
usage: grid
host: 192.0.2.2 # IP address or hostname
uuid: # The vzlogger channel uuid for power
port: 8081 # Port, optional
scale: 1 # Scale factor power, Multiply power raw value by this factor (optional)
energyuuid: # Meter reading, The vzlogger channel uuid for the meter reading (OBIS Code 1.8.0, electricity consumption) (optional)
returnenergyuuid: # Return meter reading, The vzlogger channel uuid for the return meter reading (OBIS Code 2.8.0) (optional)
energyscale: 0.001 # Scale factor energy, Multiply energy raw value by this factor (optional)
l1currentuuid: # Current on phase 1, The vzlogger channel uuid for current on phase 1 (OBIS Code 31.7.0) (optional)
l2currentuuid: # Current on phase 2, The vzlogger channel uuid for current on phase 2 (OBIS Code 51.7.0) (optional)
l3currentuuid: # Current on phase 3, The vzlogger channel uuid for current on phase 3 (OBIS Code 71.7.0) (optional)
l1poweruuid: # Power on phase 1, The vzlogger channel uuid for power on phase 1 (OBIS Code 36.7.0) (optional)
l2poweruuid: # Power on phase 2, The vzlogger channel uuid for power on phase 2 (OBIS Code 56.7.0) (optional)
l3poweruuid: # Power on phase 3, The vzlogger channel uuid for power on phase 3 (OBIS Code 76.7.0) (optional)
l1voltageuuid: # Voltage on phase 1, The vzlogger channel uuid for voltage on phase 1 (OBIS Code 32.7.0) (optional)
l2voltageuuid: # Voltage on phase 2, The vzlogger channel uuid for voltage on phase 2 (OBIS Code 52.7.0) (optional)
l3voltageuuid: # Voltage on phase 3, The vzlogger channel uuid for voltage on phase 3 (OBIS Code 72.7.0) (optional)
cache: 1s # Cache, Time interval for data refresh (optional)