Salta ai contenuti
ricarica intelligente

Zendure Hyper 2000

Questa pagina mostra la versione nightly. Passa alla versione release.

Ambiti di utilizzo

  • Produzione solare
  • Batteria

Parametri

NomeDescrizioneValoreLivello
accountAccount ID
Esempio: dev@zendure.com
facoltativo
serialSerial

You can find this in the Zendure App in the settings of the device

Esempio: VU5D99F74021B04
facoltativo
regionRegion
Predefinito: EU
facoltativo
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Predefinito: 0
Esempio: 25
facoltativo
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Predefinito: 100
Esempio: 95
facoltativo
timeoutTimeout
Esempio: 10s
facoltativo
capacity [kWh]Battery capacity
Predefinito: 2
Esempio: 50
avanzato
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

Predefinito: 1200
avanzato
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

Predefinito: 800
avanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

meters:
- name: my_pv
type: template
template: zendure-hyper
usage: pv
account: dev@zendure.com # Account ID
serial: VU5D99F74021B04 # Serial, You can find this in the Zendure App in the settings of the device
region: EU # Region, [EU, Global]
timeout: 10s # Timeout, optional
meters:
- name: my_battery
type: template
template: zendure-hyper
usage: battery
account: dev@zendure.com # Account ID
serial: VU5D99F74021B04 # Serial, You can find this in the Zendure App in the settings of the device
region: EU # Region, [EU, Global]
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
timeout: 10s # Timeout, optional
capacity: 2 # Battery capacity (kWh), optional
maxchargepower: 1200 # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: 800 # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)