Ga naar inhoud
slim laden

Cupra EU Data Act

Uses the vehicle data provided under the EU Data Act through the VW group portal. Log in with the credentials of the My CUPRA App.

Prerequisite (one-time, in a browser): log in to the portal, confirm the consent screen, link the vehicle and enable a continuous data request (every 15 minutes). Without this activation the portal returns no data. Data is provided on the portal roughly every 15 minutes.

Parameters

NaamOmschrijvingWaardeNiveau
userUsername

e.g. email address, user id, etc.

optioneel
passwordPassword

Service account password

optioneel
vinVehicle Identification Number

If you own multiple vehicles from the same manufacturer

Voorbeeld: W...
optioneel
titleTitle

Will be displayed in the user interface

optioneel
capacity [kWh]Battery capacity
Voorbeeld: 50
optioneel
iconIcon

Will be displayed in the user interface

Standaard: car
geavanceerd
phasesMaximum number of phases

Used to determine the minimum solar surplus and plan duration.

geavanceerd
minCurrent [A]Minimum current

The minimum current per connected phase that can be used

Voorbeeld: 6
geavanceerd
maxCurrent [A]Maximum current

The maximum current per connected phase that can be used

Voorbeeld: 16
geavanceerd
maxPower [W]Maximum charging power hint

Defines the maximum charging power of the vehicle. Helps improve charge plan accuracy when the vehicle typically uses less than the offered current or supports higher single-phase current compared to three-phase. The offered current of the loadpoint is not affected.

Voorbeeld: 10000
geavanceerd
identifiersRFID identification

Used to assign the vehicle to a loadpoint via RFID card. The identifier is shown on the loadpoint. Copy the value from there. Learn more.

geavanceerd
priorityPriority

Priority of the loadpoint or vehicle in relation to other loadpoints or vehicles for allocating surplus energy (higher values, higher priority).

geavanceerd
cacheCache

Time interval for data refresh

Standaard: 15m
Voorbeeld: 5m
geavanceerd
coarsecurrent1A current control

Vehicle supports 1A current steps only

geavanceerd
welcomechargeCharge on connection

Charger will enable charging for short time when vehicle is connected, irrespective of configured charge mode. This is useful for vehicles that require power supply when connecting.

geavanceerd
climaterdisabledDisable climater detection

Ignore the vehicle's climater state for charge control, so charging stops at the SoC or energy limit even when the vehicle signals an active climater request.

geavanceerd
autodetectdisabledExclude from auto detection

Ignore the vehicle for auto detection of connected vehicles

geavanceerd
wakeupdisabledDisable wake-up calls

Do not send wake-up calls to the vehicle or charger, useful for vehicles that refuse to charge after repeated wake-ups.

geavanceerd
Configuratievoorbeeld voor evcc.yaml

Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.

vehicles:
- name: my_car
type: template
template: cupra
user: # Username, e.g. email address, user id, etc.
password: # Password, Service account password
vin: W... # Vehicle Identification Number, If you own multiple vehicles from the same manufacturer (optional)
title: # Title, Will be displayed in the user interface (optional)
capacity: 50 # Battery capacity (kWh), optional
icon: car # Icon, Will be displayed in the user interface [car, bike, bus, moped, motorcycle, rocket, scooter, taxi, tractor, rickshaw, shuttle, van, airpurifier, battery, bulb, climate, coffeemaker, compute, cooking, cooler, desktop, device, dishwasher, dryer, floorlamp, generic, heater, heatexchange, heatpump, kettle, laundry, laundry2, machine, meter, microwave, pump, smartconsumer, tool, waterheater] (optional)
phases: # Maximum number of phases, Used to determine the minimum solar surplus and plan duration. [1, 2, 3] (optional)
minCurrent: 6 # Minimum current (A), The minimum current per connected phase that can be used (optional)
maxCurrent: 16 # Maximum current (A), The maximum current per connected phase that can be used (optional)
maxPower: 10000 # Maximum charging power hint (W), Defines the maximum charging power of the vehicle. Helps improve charge plan accuracy when the vehicle typically uses less than the offered current or supports higher single-phase current compared to three-phase. _The offered current of the loadpoint is not affected._ (optional)
identifiers: # RFID identification, Used to assign the vehicle to a loadpoint via RFID card. The identifier is shown on the loadpoint. Copy the value from there. [Learn more.](https://docs.evcc.io/en/docs/features/vehicle) (optional)
priority: # Priority, Priority of the loadpoint or vehicle in relation to other loadpoints or vehicles for allocating surplus energy (higher values, higher priority). (optional)
cache: 15m # Cache, Time interval for data refresh (optional)
coarsecurrent: # 1A current control, Vehicle supports 1A current steps only (optional)
welcomecharge: # Charge on connection, Charger will enable charging for short time when vehicle is connected, irrespective of configured charge mode. This is useful for vehicles that require power supply when connecting. (optional)
climaterdisabled: # Disable climater detection, Ignore the vehicle's climater state for charge control, so charging stops at the SoC or energy limit even when the vehicle signals an active climater request. (optional)
autodetectdisabled: # Exclude from auto detection, Ignore the vehicle for auto detection of connected vehicles (optional)
wakeupdisabled: # Disable wake-up calls, Do not send wake-up calls to the vehicle or charger, useful for vehicles that refuse to charge after repeated wake-ups. (optional)