Anker SOLIX X1 Hybrid Inverter

Questa pagina mostra la versione nightly. Passa alla versione release.

The Modbus TCP interface must be enabled in the Anker app. This configuration was tested with the Firmware Version 1.0.16.1. Older or newer Firmware Versions may use different register addresses and therefore deliver incorrect data. evcc can charge the battery from the grid (work mode third-party control with the maximum charge power maxchargepower) and return it to self-consumption. A work mode set in the Anker app is overwritten. evcc only writes to the X1 when a battery function is enabled (grid charging, discharge lock, automatic optimizer control or an external battery mode). Otherwise the X1 keeps the mode set in the Anker app. The X1 does not return to self-consumption on its own: if evcc stops unexpectedly while grid charging, the X1 keeps charging until evcc sets a mode again. Holding is not supported and falls back to normal operation: the X1 offers no way to block discharging while still storing PV surplus.

Funzionalità supportate

  • Controllo batteria: Controllo esterno della carica e della scarica della batteria domestica tramite evcc.

Ambiti di utilizzo

  • Contatore di rete
  • Produzione solare
  • Batteria

Parametri

NomeDescrizioneValoreLivello
idID Modbus
Predefinito: 1
intobbligatorio
hostIndirizzo IP o hostname
Esempio: 192.0.2.2
obbligatorio
portPorta
Predefinito: 502
intobbligatorio
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

facoltativo
capacity [kWh]Battery capacity
Esempio: 50
facoltativo
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Predefinito: 0
Esempio: 25
facoltativo
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Predefinito: 100
Esempio: 95
facoltativo
maxacpower [W]Maximum AC power of the hybrid inverter
Predefinito: 0
Esempio: 5000
avanzato
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avanzato
watchdogWatchdog
Predefinito: 60s
avanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

meters:
- name: my_grid
type: template
template: anker-solix-x1
usage: grid
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
watchdog: 60s # Watchdog, optional
meters:
- name: my_pv
type: template
template: anker-solix-x1
usage: pv
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
watchdog: 60s # Watchdog, optional
meters:
- name: my_battery
type: template
template: anker-solix-x1
usage: battery
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)
watchdog: 60s # Watchdog, optional