Huawei SUN2000 Hybrid Inverter
Modbus TCP requires activation within the communication settings of the inverter using an "installer account", see Modbus TCP Activation Guide.
Grid and Battery require the Huawei Smart Power Sensor (DDSU/DTSU666 or SmartPS).
Multiple LUNA2000 towers connected to the same SUN2000 inverter are configured as a single logical battery.
Curtailment will limit the export power to the desired percentage of the maximum AC power. The inverter will automatically limit the PV power to achieve this.
Funzionalità supportate
- Controllo batteria: Controllo esterno della carica e della scarica della batteria domestica tramite evcc.
- Limitabile: La produzione dell’inverter può essere limitata (ad es. § 9 EEG). Vedi Limite esterno.
- Riducibile: La potenza assorbita può essere ridotta (ad es. § 14a EnWG). Vedi Limite esterno.
Ambiti di utilizzo
- Contatore di rete
- Produzione solare
- Batteria
Parametri
| Nome | Descrizione | Valore | Livello |
|---|---|---|---|
id | ID Modbus | int | obbligatorio |
device | Nome dispositivo Adattatore USB-RS485 | obbligatorio | |
baudrate | Baudrate | obbligatorio | |
comset | ComSet Parametro di comunicazione dell’adattatore | obbligatorio | |
host | Indirizzo IP o hostname | obbligatorio | |
port | Porta | int | obbligatorio |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | facoltativo | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | facoltativo | |
capacity [kWh] | Battery capacity | facoltativo | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | facoltativo | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | facoltativo | |
maxacpower [W] | Maximum AC power of the hybrid inverter | avanzato | |
forceaccharging | Inverter cascade Keep AC charging active (except for when being dimmed) to charge the storage from other inverters via AC. May prevent standby with older firmware versions. | avanzato |
Esempio di configurazione per evcc.yaml
Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.
meters: - name: my_grid type: template template: huawei-sun2000-hybrid usage: grid
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter timeout: 5s # optional
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 502 # Port timeout: 5s # optional
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port timeout: 5s # optionalmeters: - name: my_pv type: template template: huawei-sun2000-hybrid usage: pv
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter timeout: 5s # optional
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 502 # Port timeout: 5s # optional
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port timeout: 5s # optional maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optionalmeters: - name: my_battery type: template template: huawei-sun2000-hybrid usage: battery
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter timeout: 5s # optional
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 502 # Port timeout: 5s # optional
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port timeout: 5s # optional maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) forceaccharging: false # Inverter cascade, Keep AC charging active (except for when being dimmed) to charge the storage from other inverters via AC. May prevent standby with older firmware versions. (optional)