Solplanet AI-Dongle LAN (local HTTP API)
Uses the AI-Dongle local HTTP API (e.g. BA121T-30) instead of Modbus TCP.
The inverter serial number (isn) can be read via http://<host>:8484/getdev.cgi?device=2.
Battery control charge power is fixed at 5000 W.
Funzionalità supportate
- Controllo batteria: Controllo esterno della carica e della scarica della batteria domestica tramite evcc.
Ambiti di utilizzo
- Contatore di rete
- Produzione solare
- Batteria
Parametri
| Nome | Descrizione | Valore | Livello |
|---|---|---|---|
host | IP address or hostname | facoltativo | |
serial | Inverter serial number (isn) | facoltativo | |
capacity [kWh] | Battery capacity | facoltativo | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | facoltativo | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | facoltativo | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | avanzato | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | avanzato |
Esempio di configurazione per evcc.yaml
Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.
meters: - name: my_grid type: template template: solplanet-ai-dongle usage: grid host: 192.0.2.2 # IP address or hostname serial: # Inverter serial number (isn)meters: - name: my_pv type: template template: solplanet-ai-dongle usage: pv host: 192.0.2.2 # IP address or hostname serial: # Inverter serial number (isn)meters: - name: my_battery type: template template: solplanet-ai-dongle usage: battery host: 192.0.2.2 # IP address or hostname serial: # Inverter serial number (isn) capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)