Gå til indhold
smart opladning

KEBA KeContact P20

Requires firmware version 3.10.42 (C-series) bzw. 1.11 (X-series). For phase switching the Keba phase switch (KeContact S10) is also required and the switching control via Modbus must be set in the wallbox settings. For the X-series in the web menu, for the C-series via Modbus by setting the value "3" in register 5050.

Understøttede funktioner

Parametre

NavnBeskrivelseVærdiNiveau
idModbus-ID
Standard: 1
intpåkrævet
hostIP-adresse eller værtsnavn
Eksempel: 192.0.2.2
påkrævet
portPort
Standard: 502
intpåkrævet
welcomechargeCharge on connection

Charger will enable charging for short time when vehicle is connected, irrespective of configured charge mode. This is useful for vehicles that require power supply when connecting.

avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

chargers:
- name: my_charger
type: template
template: keba-modbus
# Modbus TCP
modbus: tcpip
id: 255
host: # Hostname
port: 502 # Port
welcomecharge: # Charge on connection, Charger will enable charging for short time when vehicle is connected, irrespective of configured charge mode. This is useful for vehicles that require power supply when connecting. (optional)