Following settings have to be enabled using the KEBA eMobility App:

  • Enable Modbus: The "Enable" and "Enable RFID" options must be activated in the "Modbus" settings.
  • To use RFID cards, the "Authorization" option must be activated under "Device".
  • For phase switching the minimum firmware version 1.3.0 must be installed. In the "Photovoltaic Optimized Charging" settings, the phase switching needs to be enabled. The "communication channel" must be set to "Modbus".

Understøttede funktioner

Parametre

NavnBeskrivelseVærdiNiveau
idModbus-ID
Standard: 1
intpåkrævet
hostIP-adresse eller værtsnavn
Eksempel: 192.0.2.2
påkrævet
portPort
Standard: 502
intpåkrævet
welcomechargeCharge on connection

Charger will enable charging for short time when vehicle is connected, irrespective of configured charge mode. This is useful for vehicles that require power supply when connecting.

avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

chargers:
- name: my_charger
type: template
template: keba-modbus-p40
# Modbus TCP
modbus: tcpip
id: 255
host: # Hostname
port: 502 # Port
welcomecharge: # Charge on connection, Charger will enable charging for short time when vehicle is connected, irrespective of configured charge mode. This is useful for vehicles that require power supply when connecting. (optional)