Gå til indhold
smart opladning

Awatt Electronic HEMS PRO (EEBus)

Parametre

NavnBeskrivelseVærdiNiveau
skiSubject Key Identifier (SKI)

SKI of the FNN control box (shown in its web interface)

valgfri
ipIP address
Eksempel: 192.0.2.2
valgfri
productionnominalmax [Wp]Installed generator power

Rated generator/module power of the installation (reference value according to § 9 EEG).

valgfri
consumptionnominalmax [W]Max. consumption power (grid connection)

Contractual maximum power of the grid connection point reported to the control box. This is the connection capacity agreed with the grid operator, NOT the minimum consumption power (Pmin) of the control box.

avanceret
failsafeconsumptionpower [W]Failsafe consumption limit (Pmin, LPC)

Failsafe minimum consumption power (Pmin) for controllable loads applied when the heartbeat from the control box is lost; it is overwritten by the control box once it transmits its own failsafe values.

avanceret
failsafeproductionpower [W]Failsafe production limit (LPP)

Remaining maximum feed-in power applied when the heartbeat from the control box is lost. Initial value; it is overwritten by the control box once it transmits its own failsafe values.

avanceret
failsafedurationFailsafe minimum duration

Minimum time the failsafe limit stays active once entered. Initial value (default 2h); the control box overwrites it once it transmits its own value.

avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

hems:
type: template
template: hemspro-eebus
ski: # Subject Key Identifier (SKI), SKI of the FNN control box (shown in its web interface)
ip: 192.0.2.2 # IP address, optional
productionnominalmax: # Installed generator power (Wp), Rated generator/module power of the installation (reference value according to § 9 EEG). (optional)
consumptionnominalmax: # Max. consumption power (grid connection) (W), Contractual maximum power of the grid connection point reported to the control box. This is the connection capacity agreed with the grid operator, NOT the minimum consumption power (Pmin) of the control box. (optional)
failsafeconsumptionpower: # Failsafe consumption limit (Pmin, LPC) (W), Failsafe minimum consumption power (Pmin) for controllable loads applied when the heartbeat from the control box is lost; it is overwritten by the control box once it transmits its own failsafe values. (optional)
failsafeproductionpower: # Failsafe production limit (LPP) (W), Remaining maximum feed-in power applied when the heartbeat from the control box is lost. Initial value; it is overwritten by the control box once it transmits its own failsafe values. (optional)
failsafeduration: # Failsafe minimum duration, Minimum time the failsafe limit stays active once entered. Initial value (default 2h); the control box overwrites it once it transmits its own value. (optional)