Gå til indhold
smart opladning

Demo battery

For demonstration purposes. Battery with a fixed set of values.

Anvendelsesområder

  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
power [W]Powervalgfri
soc [%]Chargevalgfri
controllableControllable

Supports active battery control

avanceret
capacity [kWh]Battery capacity
Eksempel: 50
avanceret
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
avanceret
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Standard: 100
Eksempel: 95
avanceret
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avanceret
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avanceret
energy [kWh]Meter readingavanceret
currentL1 [A]L1 currentavanceret
currentL2 [A]L2 currentavanceret
currentL3 [A]L3 currentavanceret
maxacpower [W]Maximum AC power of the hybrid inverter
Standard: 0
Eksempel: 5000
avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_battery
type: template
template: demo-battery
usage: battery
power: # Power (W), optional
soc: # Charge (%), optional
controllable: # Controllable, Supports active battery control (optional)
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
energy: # Meter reading (kWh), optional
currentL1: # L1 current (A), optional
currentL2: # L2 current (A), optional
currentL3: # L3 current (A), optional