Gå til indhold
smart opladning

Enphase IQ Gateway

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
hostIP address or hostname
Eksempel: 192.0.2.2
valgfri
tokenToken

Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: enphase.com

valgfri
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Standard: 100
Eksempel: 95
valgfri
schemaSchema
Standard: https
avanceret
battery_typeEnphase Battery Type (AC or IQ)

Select 'iq' for new Enphase IQ Batteries. Leave at default 'ac' for older generation AC Batteries.

Standard: ac
avanceret
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avanceret
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avanceret
cacheCache

Time interval for data refresh

Standard: 1s
Eksempel: 5m
avanceret
timeoutTimeout
Standard: 10s
Eksempel: 10s
avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: enphase
usage: grid
host: 192.0.2.2 # IP address or hostname
token: # Token, Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: [enphase.com](https://enphase.com/download/accessing-iq-gateway-local-apis-or-local-ui-token-based-authentication) (optional)
schema: https # Schema, [https, http] (optional)
cache: 1s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional
meters:
- name: my_pv
type: template
template: enphase
usage: pv
host: 192.0.2.2 # IP address or hostname
token: # Token, Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: [enphase.com](https://enphase.com/download/accessing-iq-gateway-local-apis-or-local-ui-token-based-authentication) (optional)
schema: https # Schema, [https, http] (optional)
cache: 1s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional
meters:
- name: my_battery
type: template
template: enphase
usage: battery
host: 192.0.2.2 # IP address or hostname
token: # Token, Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: [enphase.com](https://enphase.com/download/accessing-iq-gateway-local-apis-or-local-ui-token-based-authentication) (optional)
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
schema: https # Schema, [https, http] (optional)
battery_type: ac # Enphase Battery Type (AC or IQ), Select 'iq' for new Enphase IQ Batteries. Leave at default 'ac' for older generation AC Batteries. [ac, iq] (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
cache: 1s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional