Fronius Primo GEN24 Plus

To use active charge control, the Energy Cost Assistant (ECA) must not be activated in Fronius Solar.web. (Fronius Solar.web -> Settings -> Operating Mode -> Self-Consumption) Meter address of primary or secondary meters: on the web interface of the inverter, only the address of the first meter (e.g., 200) can be set. Additional meters receive an ascending number (e.g., 201).

Understøttede funktioner

  • Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.
  • Kan begrænses: Inverterens produktion kan reduceres (f.eks. § 9 EEG). Se Ekstern grænse.

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
idModbus-ID
Standard: 1
intpåkrævet
hostIP-adresse eller værtsnavn
Eksempel: 192.0.2.2
påkrævet
portPort
Standard: 502
intpåkrævet
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Standard: 100
Eksempel: 95
valgfri
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avanceret
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avanceret
maxchargerate [%]Maximum charge rate

For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter.

Standard: 100
avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: fronius-gen24
usage: grid
# Modbus TCP
modbus: tcpip
id: 200
host: # Hostname
port: 502 # Port
meters:
- name: my_pv
type: template
template: fronius-gen24
usage: pv
# Modbus TCP
modbus: tcpip
id: 200
host: # Hostname
port: 502 # Port
meters:
- name: my_battery
type: template
template: fronius-gen24
usage: battery
# Modbus TCP
modbus: tcpip
id: 200
host: # Hostname
port: 502 # Port
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
maxchargerate: 100 # Maximum charge rate (%), For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. (optional)