Fronius Verto Plus
Meter address of primary or secondary meters: on the web interface of the inverter, only the address of the first meter (e.g., 200) can be set. Additional meters receive an ascending number (e.g., 201).
Understøttede funktioner
- Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.
- Kan begrænses: Inverterens produktion kan reduceres (f.eks. § 9 EEG). Se Ekstern grænse.
Anvendelsesområder
- Elnetsmåler
- Solproduktion
- Batteri
Parametre
| Navn | Beskrivelse | Værdi | Niveau |
|---|---|---|---|
id | Modbus-ID | int | påkrævet |
host | IP-adresse eller værtsnavn | påkrævet | |
port | Port | int | påkrævet |
capacity [kWh] | Battery capacity | valgfri | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | valgfri | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | valgfri | |
maxchargerate [%] | Maximum charge rate For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. | avanceret | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | avanceret | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | avanceret |
Konfigurationseksempel til evcc.yaml
Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.
meters: - name: my_grid type: template template: fronius-vertoplus usage: grid
# Modbus TCP modbus: tcpip id: 200 host: # Hostname port: 502 # Portmeters: - name: my_pv type: template template: fronius-vertoplus usage: pv
# Modbus TCP modbus: tcpip id: 200 host: # Hostname port: 502 # Portmeters: - name: my_battery type: template template: fronius-vertoplus usage: battery
# Modbus TCP modbus: tcpip id: 200 host: # Hostname port: 502 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) maxchargerate: 100 # Maximum charge rate (%), For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. (optional) maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)