Gå til indhold
smart opladning

Indevolt PowerFlex 3000 AC

Local direct access to Indevolt battery storage devices (Non-PV variants) via HTTP API on port 8080.

The device's IP address can be obtained from the Indevolt app, the router, or via UDP broadcast (port 10000). Assigning a static IP in the router is recommended.

Battery power sign convention and availability of grid import/export readings (registers 2101/2108) depend on installation (CT clamp) and should be verified.

See docs.indevolt.com.

Understøttede funktioner

  • Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.

Anvendelsesområder

  • Elnetsmåler
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
hostIP address or hostname
Eksempel: 192.0.2.2
valgfri
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Standard: 100
Eksempel: 95
valgfri
userUsername

e.g. email address, user id, etc.

avanceret
passwordPassword

Service account password

avanceret
cacheCache

Time interval for data refresh

Standard: 5s
Eksempel: 5m
avanceret
maxchargepower [W]Maximum charge power

Maximum charge power (W). Valid range 50-3000, depending on your device.

Standard: 2400
avanceret
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: indevolt-battery
usage: grid
host: 192.0.2.2 # IP address or hostname
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
cache: 5s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: indevolt-battery
usage: battery
host: 192.0.2.2 # IP address or hostname
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
cache: 5s # Cache, Time interval for data refresh (optional)
maxchargepower: 2400 # Maximum charge power (W), Maximum charge power (W). Valid range 50-3000, depending on your device. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)