Gå til indhold
smart opladning

Indevolt SolidFlex 3000 Hybrid

Local direct access to Indevolt devices (e.g. Solidflex series) via HTTP API on port 8080.

The device's IP address can be obtained from the Indevolt app, the router, or via UDP broadcast (port 10000). Assigning a static IP in the router is recommended.

Battery power sign convention and availability of grid import/export readings (registers 2101/2108) depend on installation (CT clamp) and should be verified.

See docs.indevolt.com.

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
hostIP address or hostname
Eksempel: 192.0.2.2
valgfri
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Standard: 100
Eksempel: 95
valgfri
userUsername

e.g. email address, user id, etc.

avanceret
passwordPassword

Service account password

avanceret
cacheCache

Time interval for data refresh

Standard: 5s
Eksempel: 5m
avanceret
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avanceret
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: indevolt-hybrid
usage: grid
host: 192.0.2.2 # IP address or hostname
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
cache: 5s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: indevolt-hybrid
usage: pv
host: 192.0.2.2 # IP address or hostname
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
cache: 5s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: indevolt-hybrid
usage: battery
host: 192.0.2.2 # IP address or hostname
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
cache: 5s # Cache, Time interval for data refresh (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)