Gå til indhold
smart opladning

Kostal Plenticore Hybrid

Compatible with various inverter generations (G1/G2/G3). For active battery control, the feature external battery control via Modbus must be activated using installer access.

Understøttede funktioner

  • Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.
  • Kan begrænses: Inverterens produktion kan reduceres (f.eks. § 9 EEG). Se Ekstern grænse.

Anvendelsesområder

  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
idModbus-ID
Standard: 1
intpåkrævet
hostIP-adresse eller værtsnavn
Eksempel: 192.0.2.2
påkrævet
portPort
Standard: 502
intpåkrævet
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Standard: 100
Eksempel: 95
valgfri
endiannessEndianness (Little/Big)
Standard: little
avanceret
maxacpower [W]Maximum AC power of the hybrid inverter
Standard: 0
Eksempel: 5000
avanceret
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avanceret
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avanceret
watchdogWatchdog
Standard: 60s
avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_pv
type: template
template: kostal-plenticore-gen2
usage: pv
# Modbus TCP
modbus: tcpip
id: 71
host: # Hostname
port: 1502 # Port
endianness: little # Endianness (Little/Big), [little, big] (optional)
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
watchdog: 60s # Watchdog, optional
meters:
- name: my_battery
type: template
template: kostal-plenticore-gen2
usage: battery
# Modbus TCP
modbus: tcpip
id: 71
host: # Hostname
port: 1502 # Port
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
endianness: little # Endianness (Little/Big), [little, big] (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
watchdog: 60s # Watchdog, optional