Marstek Venus E Gen 2.0
Understøttede funktioner
- Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.
Anvendelsesområder
- Batteri
Parametre
Modbus
| Navn | Beskrivelse | Værdi | Niveau |
|---|---|---|---|
id | Modbus-ID | int | påkrævet |
device | Enhedsnavn USB-RS485-adapter | påkrævet | |
baudrate | Baudrate | påkrævet | |
comset | ComSet Adapterens kommunikationsparameter | påkrævet | |
host | IP-adresse eller værtsnavn | påkrævet | |
port | Port | int | påkrævet |
generation | Generation Venus E, Venus E Gen 2.0 and Venus C are generation 2. Generation 3 uses different registers. | valgfri | |
capacity [kWh] | Battery capacity | valgfri | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | valgfri | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | valgfri | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | avanceret | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | avanceret | |
work_mode_normal | Work mode for Normal state 0=manual, 1=anti-feed, 2=trade mode. | avanceret |
Konfigurationseksempel til evcc.yaml
Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.
meters: - name: my_battery type: template template: marstek-venus-e usage: battery
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 502 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port generation: # Generation, Venus E, Venus E Gen 2.0 and Venus C are generation 2. Generation 3 uses different registers. [2, 3] capacity: 5.12 # Battery capacity (kWh), optional minsoc: 11 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) maxchargepower: 2500 # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: 800 # Maximum discharge power (W), Maximum discharge power of the storage. (optional) work_mode_normal: 1 # Work mode for Normal state, 0=manual, 1=anti-feed, 2=trade mode. (optional)