RCT Power
Understøttede funktioner
- Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.
- Kan begrænses: Inverterens produktion kan reduceres (f.eks. § 9 EEG). Se Ekstern grænse.
Anvendelsesområder
- Elnetsmåler
- Solproduktion
- Batteri
Parametre
| Navn | Beskrivelse | Værdi | Niveau |
|---|---|---|---|
host | IP address or hostname | valgfri | |
port | Port | valgfri | |
capacity [kWh] | Battery capacity | valgfri | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | valgfri | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | valgfri | |
capacity2 [kWh] | Battery capacity of the second battery | valgfri | |
maxacpower [W] | Maximum AC power of the hybrid inverter | avanceret | |
externalpower | External power Query external power of all devices connected to S0 | avanceret | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | avanceret | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | avanceret | |
cache | Cache Time interval for data refresh | avanceret |
Konfigurationseksempel til evcc.yaml
Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.
meters: - name: my_grid type: template template: rct-power usage: grid host: 192.0.2.2 # IP address or hostname port: 8899 # Port cache: 30s # Cache, Time interval for data refresh (optional)meters: - name: my_pv type: template template: rct-power usage: pv host: 192.0.2.2 # IP address or hostname port: 8899 # Port maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional externalpower: # External power, Query external power of all devices connected to S0 (optional) cache: 30s # Cache, Time interval for data refresh (optional)meters: - name: my_battery type: template template: rct-power usage: battery host: 192.0.2.2 # IP address or hostname port: 8899 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 7 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 97 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) capacity2: 50 # Battery capacity of the second battery (kWh), optional maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional) cache: 30s # Cache, Time interval for data refresh (optional)