Cloud connection via the SENEC.Connect API. A subscription key from the SENEC developer portal is required. Access is read-only, battery control is not possible.

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
tokenSubscription key

Subscription key from the SENEC developer portal (sent as header Ocp-Apim-Subscription-Key).

valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Standard: 100
Eksempel: 95
valgfri
serialSerial

Only required if multiple systems are registered in the account. Serial number (e.g. v4-00014176) or system ID (e.g. P4H1-01GU14324-0105-FD).

avanceret
maxacpower [W]Maximum AC power of the hybrid inverter
Standard: 0
Eksempel: 5000
avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: senec-connect
usage: grid
token: # Subscription key, Subscription key from the SENEC developer portal (sent as header `Ocp-Apim-Subscription-Key`).
serial: # Serial, Only required if multiple systems are registered in the account. Serial number (e.g. `v4-00014176`) or system ID (e.g. `P4H1-01GU14324-0105-FD`). (optional)
meters:
- name: my_pv
type: template
template: senec-connect
usage: pv
token: # Subscription key, Subscription key from the SENEC developer portal (sent as header `Ocp-Apim-Subscription-Key`).
serial: # Serial, Only required if multiple systems are registered in the account. Serial number (e.g. `v4-00014176`) or system ID (e.g. `P4H1-01GU14324-0105-FD`). (optional)
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
meters:
- name: my_battery
type: template
template: senec-connect
usage: battery
token: # Subscription key, Subscription key from the SENEC developer portal (sent as header `Ocp-Apim-Subscription-Key`).
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
serial: # Serial, Only required if multiple systems are registered in the account. Serial number (e.g. `v4-00014176`) or system ID (e.g. `P4H1-01GU14324-0105-FD`). (optional)