Senergy Hybrid Inverter
Anvendelsesområder
- Elnetsmåler
- Solproduktion
- Batteri
Parametre
Modbus
| Navn | Beskrivelse | Værdi | Niveau |
|---|---|---|---|
id | Modbus-ID | int | påkrævet |
device | Enhedsnavn USB-RS485-adapter | påkrævet | |
baudrate | Baudrate | påkrævet | |
comset | ComSet Adapterens kommunikationsparameter | påkrævet | |
host | IP-adresse eller værtsnavn | påkrævet | |
port | Port | int | påkrævet |
capacity [kWh] | Battery capacity | valgfri | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | valgfri | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | valgfri | |
maxacpower [W] | Maximum AC power of the hybrid inverter | avanceret | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | avanceret | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | avanceret |
Konfigurationseksempel til evcc.yaml
Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.
meters: - name: my_grid type: template template: senergy-hybrid usage: grid
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 502 # Portmeters: - name: my_pv type: template template: senergy-hybrid usage: pv
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 502 # Port maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optionalmeters: - name: my_battery type: template template: senergy-hybrid usage: battery
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 502 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 10 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) maxchargepower: 10000 # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: 10000 # Maximum discharge power (W), Maximum discharge power of the storage. (optional)