Sigenergy Sigen PV Max

Modbus TCP must be enabled in the configuration app with installer rights. This option is not available in the mySigen app for customers.

Understøttede funktioner

  • Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
idModbus-ID
Standard: 1
intpåkrævet
hostIP-adresse eller værtsnavn
Eksempel: 192.0.2.2
påkrævet
portPort
Standard: 502
intpåkrævet
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Standard: 100
Eksempel: 95
valgfri
maxacpower [W]Maximum AC power of the hybrid inverter
Standard: 0
Eksempel: 5000
avanceret
gatewaySigen Energy Gateway installed

Uses the "Backup SoC" register (40046) instead of "Discharge Cut-Off SoC" (40048) to block discharge. This keeps the house powered during a grid outage.

Standard: false
avanceret
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avanceret
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: sigenergy
usage: grid
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
meters:
- name: my_pv
type: template
template: sigenergy
usage: pv
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
meters:
- name: my_battery
type: template
template: sigenergy
usage: battery
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
gateway: false # Sigen Energy Gateway installed, Uses the "Backup SoC" register (40046) instead of "Discharge Cut-Off SoC" (40048) to block discharge. This keeps the house powered during a grid outage. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)