Gå til indhold
smart opladning

EVBox Elvi

Denne side viser nightly-versionen. Skift til release-versionen.

If the device is installed with phaserotation, this can be configured in the EVBox Elvi with the EVBox Connect App so the voltages and currents are reported on the correct phase. This is necessary for the loadmanagement of EVBox, but for the usage with evcc the phaserotation should not be configured inside the EVBox Elvi. Especially if the Elvi was used in a EVBox loadmanagement, it should be ensured in the Installationmode of the EVBox Connect App that the string under "Phaserotation" ends with "RST".

Understøttede funktioner

  • Kan nedreguleres: Effektforbruget kan reduceres (f.eks. § 14a EnWG). Se Ekstern grænse.

Parametre

NavnBeskrivelseVærdiNiveau
stationidStation ID

Unique identifier of the charger. Automatically detected once the charger connects.

Eksempel: EVB-P12354
valgfri
meterMeter ID
Standard: true
valgfri
connectorConnector number

For multi-connector stations. Numbering starts at 1.

Standard: 1
avanceret
chargingprofileCharging profile type

Use TxProfile only if the charger ignores TxDefaultProfile changes during an active transaction. Without a transaction, TxDefaultProfile is still used; an active transaction must report its ID. TxProfile expires with its transaction. The default profile is restored on the next control cycle. If evcc is offline then, the charger may charge without this limit until it reconnects.

Standard: TxDefaultProfile
avanceret
remotestartStart remote transaction on vehicle connection

Only enable this option if there is no way to initiate transactions from the charger side! This is only the case if e.g. no RFID reader is available and charging processes would have to be released individually via app. Normally, the charger should always be configured at the device so that either an RFID card is used for activation or the charger is set to "Autostart", "Free Charging" or similar. First check the documentation and configuration possibilities of the charger, ask the manufacturer if necessary! (Uses OCPP RemoteStartTransaction)

avanceret
idtagAuthentication token

This option is only required in exceptional cases if the charger requires a specific token for accepting external transactions. (Uses OCPP RemoteStartTransaction)

Eksempel: evcc
avanceret
connecttimeoutTimeout for registration

Timeout for the registration of the charging point

Standard: 5m
avanceret
metervaluesMeter values for transmission

Manual specification of the meter values to be configured (MeterValuesSampledData)

Eksempel: Energy.Active.Import.Register,Power.Active.Import,SoC,Current.Offered,Power.Offered,Current.Import,Voltage
avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

chargers:
- name: my_charger
type: template
template: ocpp-evbox-elvi
stationid: EVB-P12354 # Station ID, Unique identifier of the charger. Automatically detected once the charger connects. (optional)
meter: true # Meter ID, optional
connector: 1 # Connector number, For multi-connector stations. Numbering starts at 1. (optional)
chargingprofile: TxDefaultProfile # Charging profile type, Use TxProfile only if the charger ignores TxDefaultProfile changes during an active transaction. Without a transaction, TxDefaultProfile is still used; an active transaction must report its ID. TxProfile expires with its transaction. The default profile is restored on the next control cycle. If evcc is offline then, the charger may charge without this limit until it reconnects. [TxDefaultProfile, TxProfile] (optional)
remotestart: # Start remote transaction on vehicle connection, Only enable this option if there is no way to initiate transactions from the charger side! This is only the case if e.g. no RFID reader is available and charging processes would have to be released individually via app. Normally, the charger should always be configured at the device so that either an RFID card is used for activation or the charger is set to "Autostart", "Free Charging" or similar. First check the documentation and configuration possibilities of the charger, ask the manufacturer if necessary! (Uses OCPP RemoteStartTransaction) (optional)
idtag: evcc # Authentication token, This option is only required in exceptional cases if the charger requires a specific token for accepting external transactions. (Uses OCPP RemoteStartTransaction) (optional)
connecttimeout: 5m # Timeout for registration, Timeout for the registration of the charging point (optional)
metervalues: Energy.Active.Import.Register,Power.Active.Import,SoC,Current.Offered,Power.Offered,Current.Import,Voltage # Meter values for transmission, Manual specification of the meter values to be configured (MeterValuesSampledData) (optional)