Requires OpenEVSE WiFi firmware 4.1.9 or later. evcc controls the charger through its claims API; the manual override on the charger (the On/Off mode on its dashboard) takes precedence over evcc; tap Auto to release it. If evcc is removed, delete its claim (client 262145) in the charger's web UI or via DELETE /claims/262145. 1p/3p phase switching (phases1p3p) only works with modified 3-phase controllers that answer the $G7/$S7 RAPI commands; stock OpenEVSE controllers do not.

Understøttede funktioner

  • Indbygget måler: Understøttelse af en integreret måler.
  • Kan nedreguleres: Effektforbruget kan reduceres (f.eks. § 14a EnWG). Se Ekstern grænse.

Parametre

NavnBeskrivelseVærdiNiveau
hostIP address or hostname
Eksempel: 192.0.2.2
valgfri
userUsername

e.g. email address, user id, etc.

valgfri
passwordPassword

Service account password

valgfri
phases1p3pPhase switching

Only for modified 3-phase controllers that support $G7 and $S7

avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

chargers:
- name: my_charger
type: template
template: openevse
host: 192.0.2.2 # IP address or hostname
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
phases1p3p: # Phase switching, Only for modified 3-phase controllers that support `$G7` and `$S7` (optional)