A-Tronix AX Plus Hybrid Inverter

Denne side viser nightly-versionen. Der findes endnu ingen release-version.

Understøttede funktioner

  • Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

Modbus
NavnBeskrivelseVærdiNiveau
idModbus-ID
Standard: 1
intpåkrævet
deviceEnhedsnavn

USB-RS485-adapter

Eksempel: /dev/ttyUSB0
påkrævet
baudrateBaudrate
Standard: 9600
påkrævet
comsetComSet

Adapterens kommunikationsparameter

Standard: 8N1
påkrævet
hostIP-adresse eller værtsnavn
Eksempel: 192.0.2.2
påkrævet
portPort
Standard: 502
intpåkrævet
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

valgfri
maxdischargecurrentMax Discharge Current

Battery max discharge current in A, written back when leaving hold mode. Inverter default is 50 A for H3-Pro/Smart (26 A for H3).

valgfri
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 10
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Standard: 100
Eksempel: 95
valgfri
maxchargecurrentMax Charge Current

Battery max charge current in A, written back when leaving holdcharge mode. Inverter default is 50 A for H3-Pro/Smart.

Standard: 50
valgfri
maxacpower [W]Maximum AC power of the hybrid inverter
Standard: 0
Eksempel: 5000
avanceret
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: fox-ess-h3-smart
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 247
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 247
host: # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 247
host: # Hostname
port: 502 # Port
maxdischargecurrent: # Max Discharge Current, Battery max discharge current in A, written back when leaving hold mode. Inverter default is 50 A for H3-Pro/Smart (26 A for H3).
maxchargecurrent: 50 # Max Charge Current, Battery max charge current in A, written back when leaving holdcharge mode. Inverter default is 50 A for H3-Pro/Smart. (optional)
meters:
- name: my_pv
type: template
template: fox-ess-h3-smart
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 247
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 247
host: # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 247
host: # Hostname
port: 502 # Port
maxdischargecurrent: # Max Discharge Current, Battery max discharge current in A, written back when leaving hold mode. Inverter default is 50 A for H3-Pro/Smart (26 A for H3).
maxchargecurrent: 50 # Max Charge Current, Battery max charge current in A, written back when leaving holdcharge mode. Inverter default is 50 A for H3-Pro/Smart. (optional)
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
meters:
- name: my_battery
type: template
template: fox-ess-h3-smart
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 247
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 247
host: # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 247
host: # Hostname
port: 502 # Port
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.
maxdischargecurrent: # Max Discharge Current, Battery max discharge current in A, written back when leaving hold mode. Inverter default is 50 A for H3-Pro/Smart (26 A for H3).
capacity: 50 # Battery capacity (kWh), optional
minsoc: 10 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
maxchargecurrent: 50 # Max Charge Current, Battery max charge current in A, written back when leaving holdcharge mode. Inverter default is 50 A for H3-Pro/Smart. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)