Atmoce MG100 M-gateway
Support for Atmoce MG100 (included with MC100 and MC100-T). Requires installer to enable Modbus TCP in configuration or through Atmozen app; available in firmware 01.01.00.18.10 or later. 'Grid Recharging' and 'Export Power' must be enabled in the Atmozen app to allow battery (dis)charging to/from grid.
Understøttede funktioner
- Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.
- Kan begrænses: Inverterens produktion kan reduceres (f.eks. § 9 EEG). Se Ekstern grænse.
- Kan nedreguleres: Effektforbruget kan reduceres (f.eks. § 14a EnWG). Se Ekstern grænse.
Anvendelsesområder
- Elnetsmåler
- Solproduktion
- Batteri
Parametre
| Navn | Beskrivelse | Værdi | Niveau |
|---|---|---|---|
id | Modbus-ID | int | påkrævet |
host | IP-adresse eller værtsnavn | påkrævet | |
port | Port | int | påkrævet |
firmware | Firmware version Firmware 01.01.00.28.15 and higher allows for correct hold/holdcharge functionality, dimming and curtailing. Older versions only support hold function without (dis)charge. | valgfri | |
maxacpower [W] | Maximum AC power of the hybrid inverter | avanceret | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | avanceret | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | avanceret |
Konfigurationseksempel til evcc.yaml
Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.
meters: - name: my_grid type: template template: atmoce usage: grid
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port firmware: <01.01.00.28.15 # Firmware version, Firmware 01.01.00.28.15 and higher allows for correct hold/holdcharge functionality, dimming and curtailing. Older versions only support hold function without (dis)charge. [<01.01.00.28.15, >=01.01.00.28.15]meters: - name: my_pv type: template template: atmoce usage: pv
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port firmware: <01.01.00.28.15 # Firmware version, Firmware 01.01.00.28.15 and higher allows for correct hold/holdcharge functionality, dimming and curtailing. Older versions only support hold function without (dis)charge. [<01.01.00.28.15, >=01.01.00.28.15] maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optionalmeters: - name: my_battery type: template template: atmoce usage: battery
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port firmware: <01.01.00.28.15 # Firmware version, Firmware 01.01.00.28.15 and higher allows for correct hold/holdcharge functionality, dimming and curtailing. Older versions only support hold function without (dis)charge. [<01.01.00.28.15, >=01.01.00.28.15] minsoc: 10 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)