batterX Home
Understøttede funktioner
- Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.
Anvendelsesområder
- Elnetsmåler
- Solproduktion
- Batteri
Parametre
| Navn | Beskrivelse | Værdi | Niveau |
|---|---|---|---|
host | IP address or hostname | valgfri | |
port | Port | valgfri | |
externalpv | Needed when a second solar inverter is connected. This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc. | valgfri | |
capacity [kWh] | Battery capacity | valgfri | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | valgfri | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | valgfri | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | avanceret | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | avanceret |
Konfigurationseksempel til evcc.yaml
Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.
meters: - name: my_grid type: template template: batterX usage: grid host: 192.0.2.2 # IP address or hostname port: 80 # Port, optional externalpv: true # Needed when a second solar inverter is connected., This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc. (optional)meters: - name: my_pv type: template template: batterX usage: pv host: 192.0.2.2 # IP address or hostname port: 80 # Port, optional externalpv: true # Needed when a second solar inverter is connected., This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc. (optional)meters: - name: my_battery type: template template: batterX usage: battery host: 192.0.2.2 # IP address or hostname port: 80 # Port, optional externalpv: true # Needed when a second solar inverter is connected., This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc. (optional) capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)