Gå til indhold
smart opladning

FENECON REST-API

Denne side viser nightly-versionen. Skift til release-versionen.

License notice:

For active battery control on FENECON FEMS systems, a commercial license (FEMS App REST/JSON Write Access) is required.

FEMS documentation:
OpenEMS documentation:

Understøttede funktioner

  • Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
hostIP address or hostname
Eksempel: 192.0.2.2
valgfri
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Standard: 100
Eksempel: 95
valgfri
passwordPassword

Service account password

Standard: user
avanceret
maxacpower [W]Maximum AC power of the hybrid inverter
Standard: 0
Eksempel: 5000
avanceret
batteryControllable battery component

active battery control (REST/JSON Write Access)

Eksempel: ess0
avanceret
watchdogFEMS/OpenEMS battery control API timeout

FEMS/OpenEMS standard 60s

Standard: 60s
avanceret
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

avanceret
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avanceret
cacheCache

Time interval for data refresh

Standard: 1s
Eksempel: 5m
avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: openems
usage: grid
host: 192.0.2.2 # IP address or hostname
password: user # Password, Service account password (optional)
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: openems
usage: pv
host: 192.0.2.2 # IP address or hostname
password: user # Password, Service account password (optional)
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: openems
usage: battery
host: 192.0.2.2 # IP address or hostname
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
password: user # Password, Service account password (optional)
battery: ess0 # Controllable battery component, active battery control (REST/JSON Write Access) (optional)
watchdog: 60s # FEMS/OpenEMS battery control API timeout, FEMS/OpenEMS standard 60s (optional)
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)
cache: 1s # Cache, Time interval for data refresh (optional)