Fronius Symo GEN24 Plus
To use active charge control, the Energy Cost Assistant (ECA) must not be activated in Fronius Solar.web. (Fronius Solar.web -> Settings -> Operating Mode -> Self-Consumption) Meter address of primary or secondary meters: on the web interface of the inverter, only the address of the first meter (e.g., 200) can be set. Additional meters receive an ascending number (e.g., 201).
Understøttede funktioner
- Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.
- Kan begrænses: Inverterens produktion kan reduceres (f.eks. § 9 EEG). Se Ekstern grænse.
Anvendelsesområder
- Elnetsmåler
- Solproduktion
- Batteri
Parametre
| Navn | Beskrivelse | Værdi | Niveau |
|---|---|---|---|
id | Modbus-ID | int | påkrævet |
host | IP-adresse eller værtsnavn | påkrævet | |
port | Port | int | påkrævet |
capacity [kWh] | Battery capacity | valgfri | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | valgfri | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | valgfri | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | avanceret | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | avanceret | |
maxchargerate [%] | Maximum charge rate For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. | avanceret |
Konfigurationseksempel til evcc.yaml
Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.
meters: - name: my_grid type: template template: fronius-gen24 usage: grid
# Modbus TCP modbus: tcpip id: 200 host: # Hostname port: 502 # Portmeters: - name: my_pv type: template template: fronius-gen24 usage: pv
# Modbus TCP modbus: tcpip id: 200 host: # Hostname port: 502 # Portmeters: - name: my_battery type: template template: fronius-gen24 usage: battery
# Modbus TCP modbus: tcpip id: 200 host: # Hostname port: 502 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional) maxchargerate: 100 # Maximum charge rate (%), For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. (optional)