KACO blueplanet hybrid NH3

Denne side viser nightly-versionen. Der findes endnu ingen release-version.

For KACO blueplanet Hybrid NH3 with AI dongle/Wi-Fi stick. Modbus TCP and the local AISWEI HTTP API must be reachable at the stick's IP address (Modbus TCP port 502, device ID 3; HTTP port 8484). Battery power control uses the local fdbg.cgi endpoint. Maximum charge and discharge power are read from SunSpec Model 802. Battery charge and discharge energy are read from the local AISWEI HTTP API. Configure curtailment through a separate KACO NH3 curtailer device. The grid meter exposed through SunSpec Model 203 provides grid power, import/export energy, and per-phase measurements.

Understøttede funktioner

  • Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
idModbus-ID
Standard: 1
intpåkrævet
hostIP-adresse eller værtsnavn
Eksempel: 192.0.2.2
påkrævet
portPort
Standard: 502
intpåkrævet
batteryBattery numbervalgfri
serialInverter serial number (isn)valgfri
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Written to the inverter as the discharge limit and used by the optimizer. Only set a value supported by the battery. Minimum value is 5%.

Standard: 10
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Written to the inverter as the charge limit and used by the optimizer. Only set a value supported by the battery.

Standard: 100
Eksempel: 95
valgfri
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: kaco-nh3
usage: grid
# Modbus TCP
modbus: tcpip
id: 3
host: # Hostname
port: 502 # Port
meters:
- name: my_pv
type: template
template: kaco-nh3
usage: pv
# Modbus TCP
modbus: tcpip
id: 3
host: # Hostname
port: 502 # Port
meters:
- name: my_battery
type: template
template: kaco-nh3
usage: battery
# Modbus TCP
modbus: tcpip
id: 3
host: # Hostname
port: 502 # Port
battery: # Battery number, [1, 2]
serial: # Inverter serial number (isn)
capacity: 50 # Battery capacity (kWh), optional
minsoc: 10 # Minimum charge (%), Written to the inverter as the discharge limit and used by the optimizer. Only set a value supported by the battery. Minimum value is 5%. (optional)
maxsoc: 100 # Maximum charge (%), Written to the inverter as the charge limit and used by the optimizer. Only set a value supported by the battery. (optional)