Gå til indhold
smart opladning

Plexlog

Denne side viser nightly-versionen. Skift til release-versionen.

The values are updated approximately every 15 seconds, hence the evcc interval should not be less than 30 seconds.

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
idModbus-ID
Standard: 1
intpåkrævet
hostIP-adresse eller værtsnavn
Eksempel: 192.0.2.2
påkrævet
portPort
Standard: 502
intpåkrævet
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Standard: 100
Eksempel: 95
valgfri
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

avanceret
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: plexlog
usage: grid
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 503 # Port
timeout: 30s # optional
meters:
- name: my_pv
type: template
template: plexlog
usage: pv
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 503 # Port
timeout: 30s # optional
meters:
- name: my_battery
type: template
template: plexlog
usage: battery
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 503 # Port
timeout: 30s # optional
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)