SMA Smart Energy Hybrid Inverter

Denne side viser nightly-versionen. Skift til release-versionen.

When using active battery control by evcc, the 'Forecast-based Charging' function in the SMA portal must not be active. Otherwise, conflicts may arise when controlling the battery.

Understøttede funktioner

  • Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
idModbus-ID
Standard: 1
intpåkrævet
hostIP-adresse eller værtsnavn
Eksempel: 192.0.2.2
påkrævet
portPort
Standard: 502
intpåkrævet
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Standard: 100
Eksempel: 95
valgfri
maxacpower [W]Maximum AC power of the hybrid inverter
Standard: 0
Eksempel: 5000
avanceret
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

Standard: 4200
avanceret
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

Standard: 4200
avanceret
watchdogWatchdog
Standard: 60s
avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_pv
type: template
template: sma-hybrid
usage: pv
# Modbus TCP
modbus: tcpip
id: 3
host: # Hostname
port: 502 # Port
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
meters:
- name: my_battery
type: template
template: sma-hybrid
usage: battery
# Modbus TCP
modbus: tcpip
id: 3
host: # Hostname
port: 502 # Port
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
maxchargepower: 4200 # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: 4200 # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)
watchdog: 60s # Watchdog, optional
meters:
- name: my_grid
type: template
template: sma-hybrid
usage: grid
# Modbus TCP
modbus: tcpip
id: 3
host: # Hostname
port: 502 # Port