SofarSolar HYD 5…20K-3PH
For more details on how to establish a connection to the inverter see the Sofar Solar installation doc at homeassistant-solax-modbus.readthedocs.io.
Understøttede funktioner
- Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.
Anvendelsesområder
- Elnetsmåler
- Solproduktion
- Batteri
Parametre
| Navn | Beskrivelse | Værdi | Niveau |
|---|---|---|---|
id | Modbus-ID | int | påkrævet |
device | Enhedsnavn USB-RS485-adapter | påkrævet | |
baudrate | Baudrate | påkrævet | |
comset | ComSet Adapterens kommunikationsparameter | påkrævet | |
host | IP-adresse eller værtsnavn | påkrævet | |
port | Port | int | påkrævet |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | valgfri | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | valgfri | |
capacity [kWh] | Battery capacity | valgfri | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | valgfri | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | valgfri | |
maxacpower [W] | Maximum AC power of the hybrid inverter | avanceret | |
storageunit | Battery storage unit index In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). | avanceret | |
defaultmode | Default mode for battery control Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode) | avanceret | |
externalpower | Include external power Includes all connected external sources, like the power generation of cascaded inverters, into the PV power calculation. | avanceret |
Konfigurationseksempel til evcc.yaml
Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.
meters: - name: my_grid type: template template: sofarsolar-g3 usage: grid
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 8899 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 8899 # Portmeters: - name: my_pv type: template template: sofarsolar-g3 usage: pv
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 8899 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 8899 # Port maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional externalpower: # Include external power, Includes all connected external sources, like the power generation of cascaded inverters, into the PV power calculation. (optional)meters: - name: my_battery type: template template: sofarsolar-g3 usage: battery
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 8899 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 8899 # Port maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) storageunit: 1 # Battery storage unit index, In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). (optional) defaultmode: 0 # Default mode for battery control, Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode) (optional)