SolarMax MAX.STORAGE / MAX.STORAGE Ultimate
For batter control, the "Connectivity+" function must be activated via the Solarmax support. Available from software version 3.4.4. Without activation, the function remains without effect.
Understøttede funktioner
- Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.
Anvendelsesområder
- Elnetsmåler
- Solproduktion
- Batteri
Parametre
| Navn | Beskrivelse | Værdi | Niveau |
|---|---|---|---|
id | Modbus-ID | int | påkrævet |
host | IP-adresse eller værtsnavn | påkrævet | |
port | Port | int | påkrævet |
capacity [kWh] | Battery capacity | valgfri | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | valgfri | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | valgfri | |
maxacpower [W] | Maximum AC power of the hybrid inverter | avanceret | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | avanceret | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | avanceret | |
watchdog | Watchdog | avanceret |
Konfigurationseksempel til evcc.yaml
Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.
meters: - name: my_grid type: template template: solarmax-maxstorage usage: grid
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port watchdog: 60s # Watchdog, optionalmeters: - name: my_pv type: template template: solarmax-maxstorage usage: pv
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional watchdog: 60s # Watchdog, optionalmeters: - name: my_battery type: template template: solarmax-maxstorage usage: battery
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional) watchdog: 60s # Watchdog, optional