Uses the AI-Dongle local HTTP API (e.g. BA121T-30) instead of Modbus TCP. The inverter serial number (isn) can be read via http://<host>:8484/getdev.cgi?device=2. Battery control charge power is fixed at 5000 W.

Understøttede funktioner

  • Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
hostIP address or hostname
Eksempel: 192.0.2.2
valgfri
serialInverter serial number (isn)valgfri
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Standard: 100
Eksempel: 95
valgfri
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

avanceret
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: solplanet-ai-dongle
usage: grid
host: 192.0.2.2 # IP address or hostname
serial: # Inverter serial number (isn)
meters:
- name: my_pv
type: template
template: solplanet-ai-dongle
usage: pv
host: 192.0.2.2 # IP address or hostname
serial: # Inverter serial number (isn)
meters:
- name: my_battery
type: template
template: solplanet-ai-dongle
usage: battery
host: 192.0.2.2 # IP address or hostname
serial: # Inverter serial number (isn)
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)