Uses pypowerwall-server as backend. Reads come from its proxy API, battery control uses its authenticated /control/* routes. For battery control, PW_CONTROL_SECRET must be set on the server; reserve_hold requires pypowerwall-server v0.10.0 or later. Since pypowerwall-server v0.14.0 the server can optionally serve HTTPS on port 8775. Without a TLS reverse proxy or the HTTPS listener it stays plain HTTP; with controlSecret, prefer HTTPS or a trusted network.

Understøttede funktioner

  • Batteristyring: Ekstern styring af opladning og afladning af hjemmebatteriet via evcc.

Anvendelsesområder

  • Elnetsmåler
  • Solproduktion
  • Batteri

Parametre

NavnBeskrivelseVærdiNiveau
hostIP address or hostname
Eksempel: 192.0.2.2
valgfri
portPort
Standard: 8675
valgfri
capacity [kWh]Battery capacity
Eksempel: 50
valgfri
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standard: 0
Eksempel: 25
valgfri
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Standard: 100
Eksempel: 95
valgfri
schemaSchema

Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener.

Standard: http
avanceret
insecureAccept self-signed certificatesavanceret
cacheCache

Time interval for data refresh

Standard: 1s
Eksempel: 5m
avanceret
controlSecretControl secret

Value of PW_CONTROL_SECRET. Required for battery control, omit for read-only use.

avanceret
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

avanceret
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

avanceret
Konfigurationseksempel til evcc.yaml

Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.

meters:
- name: my_grid
type: template
template: tesla-powerwall-pypowerwall-server
usage: grid
host: 192.0.2.2 # IP address or hostname
port: 8675 # Port, optional
schema: http # Schema, Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener. [https, http] (optional)
insecure: # Accept self-signed certificates, optional
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: tesla-powerwall-pypowerwall-server
usage: pv
host: 192.0.2.2 # IP address or hostname
port: 8675 # Port, optional
schema: http # Schema, Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener. [https, http] (optional)
insecure: # Accept self-signed certificates, optional
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: tesla-powerwall-pypowerwall-server
usage: battery
host: 192.0.2.2 # IP address or hostname
port: 8675 # Port, optional
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
schema: http # Schema, Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener. [https, http] (optional)
insecure: # Accept self-signed certificates, optional
cache: 1s # Cache, Time interval for data refresh (optional)
controlSecret: # Control secret, Value of PW_CONTROL_SECRET. Required for battery control, omit for read-only use. (optional)
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)