VARTA element
PV is only available with an additional PV sensor, as the power of the devices registered in the SUNSPEC Manager is not output via Modbus. Element backup requires at least firmware version F21000612. The firmware update is not rolled out automatically, but can be released upon request by VARTA's technical service.
Anvendelsesområder
- Elnetsmåler
- Solproduktion
- Batteri
Parametre
| Navn | Beskrivelse | Værdi | Niveau |
|---|---|---|---|
id | Modbus-ID | int | påkrævet |
host | IP-adresse eller værtsnavn | påkrævet | |
port | Port | int | påkrævet |
capacity [kWh] | Battery capacity | valgfri | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | valgfri | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | valgfri | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | avanceret | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | avanceret | |
watchdog | Watchdog | avanceret |
Konfigurationseksempel til evcc.yaml
Hvis du ikke vil konfigurere via webgrænsefladen, kan du i stedet bruge denne YAML-blok.
meters: - name: my_grid type: template template: varta usage: grid
# Modbus TCP modbus: tcpip id: 255 host: # Hostname port: 502 # Portmeters: - name: my_pv type: template template: varta usage: pv
# Modbus TCP modbus: tcpip id: 255 host: # Hostname port: 502 # Portmeters: - name: my_battery type: template template: varta usage: battery
# Modbus TCP modbus: tcpip id: 255 host: # Hostname port: 502 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: 4000 # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional) watchdog: 120s # Watchdog, optional