OCPP 1.6J compatible

With OCPP the connection will be established from charger (client) to evcc (server). The charger needs to be able to reach evcc via the host name (functioning DNS resolution required!) or via the IP address on port 8887. By default, the first incoming connection with any station identifier is used. In order to be able to clearly assign several charging points, the respective station identifier (stationid: ) and connector number (connector: ) must be configured. Many wallboxes automatically add the station id to the backend URL, some have to do this manually ws://<evcc-host>:8887/<stationid>. If the charger supports sending metering values, try to adjust the interval to a short time span (< 10s) . Use your RFID tags (this allows e.g. vehicle identification) or set your charger to "free charging" or "autostart" to generate the transaction required for charging release.

If the charger does not offer any option to start transactions locally, the remotestart advanced option can be used to automatically start a transaction as soon as a vehicle is connected. This should only be necessary in exceptional cases.

Requirements:

  • If necessary, remove previously configured OCPP profiles (e.g. used for a different backend connection) in the charger configuration
  • Backend URL (Central System) in the charger configuration: ws://<evcc-host>:8887/ (possibly add stationid)
  • Protocol: OCPP-J v1.6, ocpp16j, JSON, Websocket, ws:// or similar
  • No encryption, no authentication, no password
  • Local network connection

The specific configuration and the actual usable functionality depend on the charger model and its software.

Fonctionnalités prises en charge

  • Régulation en mA: Régulation plus fine du courant de charge (mA au lieu de A) pour mieux exploiter le surplus solaire.
  • RFID: Lecteur de cartes RFID intégré pour l’identification du véhicule.
  • 1P/3P: Commutation automatique des phases. Utile pour la charge sur surplus solaire.
  • Modulable: La puissance consommée peut être réduite (p. ex. § 14a EnWG). Voir Limite externe.

Paramètres

NomDescriptionValeurNiveau
stationidStation ID

Unique identifier of the charger. Automatically detected once the charger connects.

Exemple: EVB-P12354
facultatif
connectorConnector number

For multi-connector stations. Numbering starts at 1.

Par défaut: 1
avancé
chargingprofileCharging profile type

Use TxProfile only if the charger ignores TxDefaultProfile changes during an active transaction. Without a transaction, TxDefaultProfile is still used; an active transaction must report its ID. TxProfile expires with its transaction. The default profile is restored on the next control cycle. If evcc is offline then, the charger may charge without this limit until it reconnects.

Par défaut: TxDefaultProfile
avancé
remotestartStart remote transaction on vehicle connection

Only enable this option if there is no way to initiate transactions from the charger side! This is only the case if e.g. no RFID reader is available and charging processes would have to be released individually via app. Normally, the charger should always be configured at the device so that either an RFID card is used for activation or the charger is set to "Autostart", "Free Charging" or similar. First check the documentation and configuration possibilities of the charger, ask the manufacturer if necessary! (Uses OCPP RemoteStartTransaction)

avancé
idtagAuthentication token

This option is only required in exceptional cases if the charger requires a specific token for accepting external transactions. (Uses OCPP RemoteStartTransaction)

Exemple: evcc
avancé
connecttimeoutTimeout for registration

Timeout for the registration of the charging point

Par défaut: 5m
avancé
meterintervalTransmission interval for meter values

Time interval for transmission of meter values (MeterValueSampleInterval)

Par défaut: 10s
avancé
metervaluesMeter values for transmission

Manual specification of the meter values to be configured (MeterValuesSampledData)

Exemple: Energy.Active.Import.Register,Power.Active.Import,SoC,Current.Offered,Power.Offered,Current.Import,Voltage
avancé
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

chargers:
- name: my_charger
type: template
template: ocpp
stationid: EVB-P12354 # Station ID, Unique identifier of the charger. Automatically detected once the charger connects. (optional)
connector: 1 # Connector number, For multi-connector stations. Numbering starts at 1. (optional)
chargingprofile: TxDefaultProfile # Charging profile type, Use TxProfile only if the charger ignores TxDefaultProfile changes during an active transaction. Without a transaction, TxDefaultProfile is still used; an active transaction must report its ID. TxProfile expires with its transaction. The default profile is restored on the next control cycle. If evcc is offline then, the charger may charge without this limit until it reconnects. [TxDefaultProfile, TxProfile] (optional)
remotestart: # Start remote transaction on vehicle connection, Only enable this option if there is no way to initiate transactions from the charger side! This is only the case if e.g. no RFID reader is available and charging processes would have to be released individually via app. Normally, the charger should always be configured at the device so that either an RFID card is used for activation or the charger is set to "Autostart", "Free Charging" or similar. First check the documentation and configuration possibilities of the charger, ask the manufacturer if necessary! (Uses OCPP RemoteStartTransaction) (optional)
idtag: evcc # Authentication token, This option is only required in exceptional cases if the charger requires a specific token for accepting external transactions. (Uses OCPP RemoteStartTransaction) (optional)
connecttimeout: 5m # Timeout for registration, Timeout for the registration of the charging point (optional)
meterinterval: 10s # Transmission interval for meter values, Time interval for transmission of meter values (MeterValueSampleInterval) (optional)
metervalues: Energy.Active.Import.Register,Power.Active.Import,SoC,Current.Offered,Power.Offered,Current.Import,Voltage # Meter values for transmission, Manual specification of the meter values to be configured (MeterValuesSampledData) (optional)