Shelly i3
Connect the relay contacts of the control box to the inputs SW1 to SW3. With three inputs only the feed-in limitation (W3, S1, S2) is mapped by default. Dimming of controllable loads (W4) requires reassigning one of the inputs.
Paramètres
| Nom | Description | Valeur | Niveau |
|---|---|---|---|
host | IP address or hostname | facultatif | |
w3input | W3 input Input number for the W3 signal (Zero export, 0%), 1 to 3 (SW1 = 1) | facultatif | |
user | Username Only required if authentication is enabled on the device | facultatif | |
password | Password Service account password | facultatif | |
productionnominalmax [Wp] | Installed generator power Rated generator/module power of the installation (reference value according to § 9 EEG). | facultatif | |
s1input | S1 input Input number for the S1 signal (60% export power limit), 1 to 3 (SW1 = 1) | facultatif | |
s2input | S2 input Input number for the S2 signal (30% export power limit), 1 to 3 (SW1 = 1) | facultatif | |
w4input | W4 input Input number for the W4 signal (Dimmer for controllable loads), 1 to 3 (SW1 = 1). Not mapped by default. | avancé | |
maxconsumptionpower [W] | Guaranteed minimum power (Pmin) Power limit applied to the root circuit while the limit is active. Required if W4 is mapped. | avancé |
Exemple de configuration pour evcc.yaml
Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.
hems: type: template template: fnn-shelly-i3 host: 192.0.2.2 # IP address or hostname w3input: 1 # W3 input, Input number for the W3 signal (Zero export, 0%), 1 to 3 (SW1 = 1) user: # Username, Only required if authentication is enabled on the device (optional) password: # Password, Service account password (optional) productionnominalmax: # Installed generator power (Wp), Rated generator/module power of the installation (reference value according to § 9 EEG). (optional) s1input: 2 # S1 input, Input number for the S1 signal (60% export power limit), 1 to 3 (SW1 = 1) (optional) s2input: 3 # S2 input, Input number for the S2 signal (30% export power limit), 1 to 3 (SW1 = 1) (optional) w4input: # W4 input, Input number for the W4 signal (Dimmer for controllable loads), 1 to 3 (SW1 = 1). Not mapped by default. (optional) maxconsumptionpower: # Guaranteed minimum power (Pmin) (W), Power limit applied to the root circuit while the limit is active. Required if W4 is mapped. (optional)