Alpha ESS Storion SMILE

To use active battery control, times for grid charging must be defined once via the web interface or app. (Settings->Function settings->Grid charging/discharging) A continuous time period should be entered here (e.g.: Charging time 1 00:00-23:00, Charging time 2 23:00-00:00). However, deactivate the "Grid charging" switch. The actual control takes place via evcc. Discharge stop is realized via a scheduled grid charge with a target SoC of 10%. Alternatively, it can also be configured via Modbus. To do this, set the registers 2134,2142,2135,2136,2144,2137,2175 to the values 0,0,23,0,23,0,0,0,0.

Fonctionnalités prises en charge

  • Pilotage de la batterie: Pilotage externe de la charge et de la décharge de la batterie domestique par evcc.

Domaines d’utilisation

  • Compteur avant réseau
  • Production solaire
  • Batterie

Paramètres

Modbus
NomDescriptionValeurNiveau
idID Modbus
Par défaut: 1
intobligatoire
deviceNom du périphérique

Adaptateur USB-RS485

Exemple: /dev/ttyUSB0
obligatoire
baudrateDébit en bauds
Par défaut: 9600
obligatoire
comsetComSet

Paramètre de communication de l’adaptateur

Par défaut: 8N1
obligatoire
hostAdresse IP ou nom d’hôte
Exemple: 192.0.2.2
obligatoire
portPort
Par défaut: 502
intobligatoire
capacity [kWh]Battery capacity
Exemple: 50
facultatif
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Par défaut: 0
Exemple: 25
facultatif
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Par défaut: 100
Exemple: 95
facultatif
maxacpower [W]Maximum AC power of the hybrid inverter
Par défaut: 0
Exemple: 5000
avancé
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avancé
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avancé
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

meters:
- name: my_grid
type: template
template: alpha-ess-smile
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 85
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 85
host: # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 85
host: # Hostname
port: 502 # Port
meters:
- name: my_pv
type: template
template: alpha-ess-smile
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 85
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 85
host: # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 85
host: # Hostname
port: 502 # Port
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
meters:
- name: my_battery
type: template
template: alpha-ess-smile
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 85
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 85
host: # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 85
host: # Hostname
port: 502 # Port
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)