batterX Home
Fonctionnalités prises en charge
- Pilotage de la batterie: Pilotage externe de la charge et de la décharge de la batterie domestique par evcc.
Domaines d’utilisation
- Compteur avant réseau
- Production solaire
- Batterie
Paramètres
| Nom | Description | Valeur | Niveau |
|---|---|---|---|
host | IP address or hostname | facultatif | |
port | Port | facultatif | |
externalpv | Needed when a second solar inverter is connected. This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc. | facultatif | |
capacity [kWh] | Battery capacity | facultatif | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | facultatif | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | facultatif | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | avancé | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | avancé |
Exemple de configuration pour evcc.yaml
Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.
meters: - name: my_grid type: template template: batterX usage: grid host: 192.0.2.2 # IP address or hostname port: 80 # Port, optional externalpv: true # Needed when a second solar inverter is connected., This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc. (optional)meters: - name: my_pv type: template template: batterX usage: pv host: 192.0.2.2 # IP address or hostname port: 80 # Port, optional externalpv: true # Needed when a second solar inverter is connected., This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc. (optional)meters: - name: my_battery type: template template: batterX usage: battery host: 192.0.2.2 # IP address or hostname port: 80 # Port, optional externalpv: true # Needed when a second solar inverter is connected., This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc. (optional) capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)