Aller au contenu
recharge intelligente

EcoFlow Stream

To use the EcoFlow Stream meter you need:

  • A valid Access Key from the EcoFlow Developer Console
  • The corresponding Secret Key
  • The main device serial number of your Stream system

These credentials can be obtained through the EcoFlow Developer Console after registering your application.

In normal operation the Backup Reserve is set to minsoc, for grid charging to maxsoc.

Note: Active battery control overwrites the Backup Reserve configured in the EcoFlow app. The device requires the Backup Reserve to exceed the discharge limit by 3, lower minsoc values are raised accordingly. Without minsoc the battery discharges down to the device's own discharge limit.

Fonctionnalités prises en charge

  • Pilotage de la batterie: Pilotage externe de la charge et de la décharge de la batterie domestique par evcc.

Domaines d’utilisation

  • Compteur avant réseau
  • Production solaire
  • Batterie

Paramètres

NomDescriptionValeurNiveau
accesskeyAccess Key

Access Key from EcoFlow Developer Console

facultatif
secretkeySecret Key

Secret Key from EcoFlow Developer Console

facultatif
serialSerial

Serial number of the main device in your Stream system, normally the first device of your system

facultatif
capacity [kWh]Battery capacity
Exemple: 50
facultatif
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Par défaut: 0
Exemple: 25
facultatif
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Par défaut: 100
Exemple: 95
facultatif
regionAPI Region

If you sometimes see error code 8513, like for example Starlink users do, automatic region detection fails. Here, you can set the API region manually. Possible values: auto (default), europe, or america.

Par défaut: auto
avancé
cacheCache

Time interval for data refresh

Par défaut: 30s
Exemple: 5m
avancé
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avancé
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avancé
Exemple de configuration pour evcc.yaml

Si vous ne souhaitez pas passer par l’interface, vous pouvez utiliser ce bloc YAML à la place.

meters:
- name: my_grid
type: template
template: ecoflow-stream
usage: grid
accesskey: # Access Key, Access Key from EcoFlow Developer Console
secretkey: # Secret Key, Secret Key from EcoFlow Developer Console
serial: # Serial, Serial number of the main device in your Stream system, normally the first device of your system
region: auto # API Region, If you sometimes see error code 8513, like for example Starlink users do, automatic region detection fails. Here, you can set the API region manually. Possible values: auto (default), europe, or america. [auto, europe, america] (optional)
cache: 30s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: ecoflow-stream
usage: pv
accesskey: # Access Key, Access Key from EcoFlow Developer Console
secretkey: # Secret Key, Secret Key from EcoFlow Developer Console
serial: # Serial, Serial number of the main device in your Stream system, normally the first device of your system
region: auto # API Region, If you sometimes see error code 8513, like for example Starlink users do, automatic region detection fails. Here, you can set the API region manually. Possible values: auto (default), europe, or america. [auto, europe, america] (optional)
cache: 30s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: ecoflow-stream
usage: battery
accesskey: # Access Key, Access Key from EcoFlow Developer Console
secretkey: # Secret Key, Secret Key from EcoFlow Developer Console
serial: # Serial, Serial number of the main device in your Stream system, normally the first device of your system
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
region: auto # API Region, If you sometimes see error code 8513, like for example Starlink users do, automatic region detection fails. Here, you can set the API region manually. Possible values: auto (default), europe, or america. [auto, europe, america] (optional)
cache: 30s # Cache, Time interval for data refresh (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)